Guides / Sprinklers · Updated
Rain Bird 5000 nozzle chart
From Rain Bird's 5000 Series charts. Standard nozzle rates are for half-circle operation; zero wind; ASABE S398.1 tests.
A 5000 rotor comes with a tree of standard Rain Curtain nozzles numbered by flow. They aren't matched: pick a bigger nozzle for a full circle and a smaller one for a quarter, so each head puts down the same rate. A quarter circle wants about a quarter of the full-circle flow. The 5000 MPR nozzles do that for you: each set (25, 30 or 35 ft) has quarter, third, half and full nozzles at about 0.6 in/hr, the same as Rain Bird's R-VAN rotary nozzles, so they can share a zone.
Standard nozzles
| Nozzle | psi | Radius (ft) | gpm | in/hr square | in/hr triangle | Min. for ½ in |
|---|---|---|---|---|---|---|
| 1.5 | 25 | 33 | 1.12 | 0.20 | 0.23 | 150 |
| 2.0 | 25 | 35 | 1.50 | 0.24 | 0.27 | 125 |
| 2.5 | 25 | 35 | 1.81 | 0.28 | 0.33 | 107 |
| 3.0 | 25 | 36 | 2.26 | 0.34 | 0.39 | 88 |
| 4.0 | 25 | 36 | 2.91 | 0.43 | 0.49 | 70 |
| 5.0 | 25 | 37 | 3.72 | 0.52 | 0.60 | 58 |
| 6.0 | 25 | 37 | 4.25 | 0.60 | 0.69 | 50 |
| 8.0 | 25 | 33 | 5.90 | 1.26 | 1.50 | 24 |
| 1.5 | 35 | 34 | 1.35 | 0.22 | 0.26 | 136 |
| 2.0 | 35 | 36 | 1.81 | 0.27 | 0.31 | 111 |
| 2.5 | 35 | 37 | 2.17 | 0.31 | 0.35 | 97 |
| 3.0 | 35 | 38 | 2.71 | 0.36 | 0.42 | 83 |
| 4.0 | 35 | 40 | 3.50 | 0.42 | 0.49 | 71 |
| 5.0 | 35 | 41 | 4.47 | 0.51 | 0.59 | 59 |
| 6.0 | 35 | 43 | 5.23 | 0.54 | 0.63 | 56 |
| 8.0 | 35 | 41 | 7.06 | 0.94 | 1.10 | 32 |
| 1.5 | 45 | 35 | 1.54 | 0.24 | 0.28 | 125 |
| 2.0 | 45 | 37 | 2.07 | 0.29 | 0.34 | 103 |
| 2.5 | 45 | 37 | 2.51 | 0.35 | 0.41 | 86 |
| 3.0 | 45 | 39 | 3.09 | 0.37 | 0.43 | 81 |
| 4.0 | 45 | 42 | 4.01 | 0.44 | 0.51 | 68 |
| 5.0 | 45 | 43 | 5.09 | 0.48 | 0.56 | 63 |
| 6.0 | 45 | 44 | 6.01 | 0.59 | 0.69 | 51 |
| 8.0 | 45 | 44 | 8.03 | 0.92 | 1.06 | 33 |
| 1.5 | 55 | 35 | 1.71 | 0.27 | 0.31 | 111 |
| 2.0 | 55 | 37 | 2.30 | 0.32 | 0.37 | 94 |
| 2.5 | 55 | 37 | 2.76 | 0.39 | 0.45 | 77 |
| 3.0 | 55 | 40 | 3.47 | 0.42 | 0.48 | 71 |
| 4.0 | 55 | 42 | 4.44 | 0.48 | 0.56 | 63 |
| 5.0 | 55 | 45 | 5.66 | 0.54 | 0.62 | 56 |
| 6.0 | 55 | 50 | 6.63 | 0.51 | 0.59 | 59 |
| 8.0 | 55 | 47 | 8.86 | 0.80 | 0.93 | 38 |
| 1.5 | 65 | 34 | 1.86 | 0.31 | 0.36 | 97 |
| 2.0 | 65 | 35 | 2.52 | 0.40 | 0.46 | 75 |
| 2.5 | 65 | 37 | 3.01 | 0.42 | 0.49 | 71 |
| 3.0 | 65 | 40 | 3.78 | 0.45 | 0.53 | 67 |
| 4.0 | 65 | 42 | 4.83 | 0.53 | 0.61 | 57 |
| 5.0 | 65 | 45 | 6.16 | 0.59 | 0.68 | 51 |
| 6.0 | 65 | 50 | 7.22 | 0.55 | 0.64 | 55 |
| 8.0 | 65 | 48 | 9.63 | 0.84 | 0.97 | 36 |
MPR nozzles
| Nozzle | psi | Radius (ft) | gpm | in/hr square | in/hr triangle | Min. for ½ in |
|---|---|---|---|---|---|---|
| 25 ft quarter | 25 | 23 | 0.74 | 0.54 | 0.62 | 56 |
| 25 ft quarter | 35 | 24 | 0.88 | 0.59 | 0.68 | 51 |
| 25 ft quarter | 45 | 25 | 1.00 | 0.62 | 0.71 | 48 |
| 25 ft quarter | 55 | 25 | 1.11 | 0.68 | 0.79 | 44 |
| 25 ft quarter | 65 | 25 | 1.21 | 0.75 | 0.86 | 40 |
| 25 ft third | 25 | 23 | 1.00 | 0.55 | 0.63 | 55 |
| 25 ft third | 35 | 24 | 1.21 | 0.61 | 0.70 | 49 |
| 25 ft third | 45 | 25 | 1.38 | 0.64 | 0.74 | 47 |
| 25 ft third | 55 | 25 | 1.53 | 0.71 | 0.82 | 42 |
| 25 ft third | 65 | 25 | 1.67 | 0.77 | 0.89 | 39 |
| 25 ft half | 25 | 23 | 1.44 | 0.52 | 0.61 | 58 |
| 25 ft half | 35 | 24 | 1.73 | 0.58 | 0.67 | 52 |
| 25 ft half | 45 | 25 | 1.98 | 0.61 | 0.70 | 49 |
| 25 ft half | 55 | 25 | 2.21 | 0.68 | 0.79 | 44 |
| 25 ft half | 65 | 25 | 2.41 | 0.74 | 0.86 | 41 |
| 25 ft full | 25 | 23 | 2.78 | 0.51 | 0.58 | 59 |
| 25 ft full | 35 | 24 | 3.34 | 0.56 | 0.64 | 54 |
| 25 ft full | 45 | 25 | 3.82 | 0.59 | 0.68 | 51 |
| 25 ft full | 55 | 25 | 4.25 | 0.65 | 0.76 | 46 |
| 25 ft full | 65 | 25 | 4.63 | 0.71 | 0.82 | 42 |
| 30 ft quarter | 25 | 29 | 1.03 | 0.47 | 0.54 | 64 |
| 30 ft quarter | 35 | 30 | 1.23 | 0.53 | 0.61 | 57 |
| 30 ft quarter | 45 | 30 | 1.40 | 0.60 | 0.69 | 50 |
| 30 ft quarter | 55 | 30 | 1.56 | 0.67 | 0.77 | 45 |
| 30 ft quarter | 65 | 30 | 1.69 | 0.72 | 0.83 | 42 |
| 30 ft third | 25 | 29 | 1.34 | 0.46 | 0.53 | 65 |
| 30 ft third | 35 | 30 | 1.62 | 0.52 | 0.60 | 58 |
| 30 ft third | 45 | 30 | 1.85 | 0.59 | 0.69 | 51 |
| 30 ft third | 55 | 30 | 2.06 | 0.66 | 0.76 | 45 |
| 30 ft third | 65 | 30 | 2.24 | 0.72 | 0.83 | 42 |
| 30 ft half | 25 | 29 | 2.15 | 0.49 | 0.57 | 61 |
| 30 ft half | 35 | 30 | 2.59 | 0.55 | 0.64 | 55 |
| 30 ft half | 45 | 30 | 2.96 | 0.63 | 0.73 | 48 |
| 30 ft half | 55 | 30 | 3.30 | 0.71 | 0.82 | 42 |
| 30 ft half | 65 | 30 | 3.60 | 0.77 | 0.89 | 39 |
| 30 ft full | 25 | 29 | 4.24 | 0.49 | 0.56 | 61 |
| 30 ft full | 35 | 30 | 5.08 | 0.54 | 0.63 | 56 |
| 30 ft full | 45 | 30 | 5.78 | 0.62 | 0.71 | 48 |
| 30 ft full | 55 | 30 | 6.39 | 0.68 | 0.79 | 44 |
| 30 ft full | 65 | 30 | 6.92 | 0.74 | 0.85 | 41 |
| 35 ft quarter | 25 | 32 | 1.40 | 0.53 | 0.61 | 57 |
| 35 ft quarter | 35 | 34 | 1.67 | 0.56 | 0.64 | 54 |
| 35 ft quarter | 45 | 35 | 1.92 | 0.60 | 0.70 | 50 |
| 35 ft quarter | 55 | 35 | 2.13 | 0.67 | 0.77 | 45 |
| 35 ft quarter | 65 | 35 | 2.31 | 0.73 | 0.84 | 41 |
| 35 ft third | 25 | 32 | 1.77 | 0.50 | 0.58 | 60 |
| 35 ft third | 35 | 34 | 2.15 | 0.54 | 0.62 | 56 |
| 35 ft third | 45 | 35 | 2.46 | 0.58 | 0.67 | 52 |
| 35 ft third | 55 | 35 | 2.74 | 0.65 | 0.75 | 46 |
| 35 ft third | 65 | 35 | 2.99 | 0.70 | 0.81 | 43 |
| 35 ft half | 25 | 32 | 2.75 | 0.52 | 0.60 | 58 |
| 35 ft half | 35 | 34 | 3.33 | 0.55 | 0.64 | 55 |
| 35 ft half | 45 | 35 | 3.81 | 0.60 | 0.69 | 50 |
| 35 ft half | 55 | 35 | 4.23 | 0.66 | 0.77 | 45 |
| 35 ft half | 65 | 35 | 4.62 | 0.73 | 0.84 | 41 |
| 35 ft full | 25 | 32 | 5.36 | 0.50 | 0.58 | 60 |
| 35 ft full | 35 | 34 | 6.62 | 0.55 | 0.64 | 55 |
| 35 ft full | 45 | 35 | 7.58 | 0.60 | 0.69 | 50 |
| 35 ft full | 55 | 35 | 8.43 | 0.66 | 0.76 | 45 |
| 35 ft full | 65 | 35 | 9.18 | 0.72 | 0.83 | 42 |
3500 Series (smaller rotor)
| Nozzle | psi | Radius (ft) | gpm | in/hr square | in/hr triangle | Min. for ½ in |
|---|---|---|---|---|---|---|
| 0.75 | 25 | 15 | 0.54 | 0.46 | 0.53 | 65 |
| 1.0 | 25 | 20 | 0.77 | 0.37 | 0.43 | 81 |
| 1.5 | 25 | 23 | 1.06 | 0.39 | 0.45 | 77 |
| 2.0 | 25 | 27 | 1.40 | 0.37 | 0.43 | 81 |
| 3.0 | 25 | 29 | 2.17 | 0.50 | 0.57 | 60 |
| 4.0 | 25 | 31 | 2.97 | 0.59 | 0.69 | 51 |
| 0.75 | 35 | 17 | 0.67 | 0.45 | 0.52 | 67 |
| 1.0 | 35 | 21 | 0.92 | 0.40 | 0.46 | 75 |
| 1.5 | 35 | 23 | 1.28 | 0.47 | 0.54 | 64 |
| 2.0 | 35 | 27 | 1.69 | 0.45 | 0.52 | 67 |
| 3.0 | 35 | 31 | 2.60 | 0.52 | 0.60 | 58 |
| 4.0 | 35 | 33 | 3.58 | 0.63 | 0.73 | 48 |
| 0.75 | 45 | 17 | 0.77 | 0.51 | 0.59 | 59 |
| 1.0 | 45 | 21 | 1.06 | 0.46 | 0.53 | 65 |
| 1.5 | 45 | 24 | 1.48 | 0.49 | 0.57 | 61 |
| 2.0 | 45 | 27 | 1.93 | 0.51 | 0.59 | 59 |
| 3.0 | 45 | 31 | 3.00 | 0.60 | 0.69 | 50 |
| 4.0 | 45 | 35 | 4.13 | 0.65 | 0.75 | 46 |
| 0.75 | 55 | 18 | 0.85 | 0.51 | 0.58 | 59 |
| 1.0 | 55 | 22 | 1.18 | 0.47 | 0.54 | 64 |
| 1.5 | 55 | 24 | 1.65 | 0.55 | 0.64 | 55 |
| 2.0 | 55 | 28 | 2.15 | 0.53 | 0.61 | 57 |
| 3.0 | 55 | 32 | 3.25 | 0.61 | 0.71 | 49 |
| 4.0 | 55 | 35 | 4.60 | 0.72 | 0.83 | 42 |
How to read it
gpm is what one nozzle uses: add them up for a zone and keep it under what your water supply gives (our pressure and flow test works that out). in/hr is how fast water lands when heads are spaced head to head, at 50% of the throw diameter: square is a grid, triangle is staggered rows. Min. for ½ in is how long a zone runs to put down half an inch at the square rate. For your own lawn, soil and watering days, use the sprinkler run time calculator.
Sources: 5000 Series nozzle chart, 5000 MPR nozzle chart, 3500 Series chart.