Georgia minimum
1,000 gallons
The smallest tank Georgia Rule 511-3-1-.05(3) allows for 3 bedrooms. The county permit and a licensed designer set the tank actually installed, and it may be bigger.
- State minimum
- 1,000 galGeorgia Rule 511-3-1-.05(3)
- Pump about every
- 2½ years4 people, year-round
- Pumping cost
- $225 to $1,2304 price guides
Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.
Keep roof water off the drainfieldSize a dry well for a downspout
Wet yard?Gravel and pipe for a French drain
How old is the house?When it was built, by address
511-3-1-.05(3): 1,000 gal for up to four bedrooms = 1,000 gal
Penn State Extension: 1,000 gal row, 4 people = 2.6 years
Georgia DPH Table 15.L: 1,000 gal row, 4 people = 2.6 years
Pumping: lowest guide low to highest guide high = $225 to $1,230 (not an average)
Shape from Virginia’s typical 900 gallon tank (12VAC5-610-815 Table 5.3: 8 × 4 ft, 4 ft of liquid, 1 ft above it). The baffle and slot follow Texas (§285.32: the first compartment half to two thirds of the tank, the slot 25 to 50% down the liquid, the inlet at least 3 in above the outlet); the outlet tee reaches 40% of the liquid depth (Pennsylvania § 73.31). Sludge settles, scum floats; EPA says pump when the sludge top is within 12 in of the outlet or the scum bottom within 6 in.
Pumping cost, by price guide
1,000 gal- Fixr, Jan 20251,000 gallon tank$225 to $400
- Thumbtack, Oct 2026National average range from its own data (its text also says $200 to $500 on average); any size$315 to $1,230
- LawnStarter, Aug 2023National average for pumping and cleaning; any size$294 to $563
- Bob Vila, Jan 2023Average to pump out a tank; any size$250 to $600
Fixr prices by tank size; Thumbtack, LawnStarter and Bob Vila give one national figure for any tank. Fixr adds $100 to $200 for a riser if the lid is buried. Shown side by side, never averaged.
Years between pumpings
1,000 gal, 4 people- Penn State Extension1,000 gallon row2.6 years
- Georgia DPH Table 15.L1,000 gallon row2.6 years
Estimates for a home lived in year-round. Water use, a disposal and what goes down the drain change it; the pumper measures the sludge and scum.
Minimum tank by state, same home
3 bedrooms- California (San Diego County)San Diego County LAMP, Table 7.2-11,000 gal
- FloridaFlorida Rule 62-6.008, Tables I and II900 gal
- GeorgiaGeorgia Rule 511-3-1-.05(3)1,000 gal
- MinnesotaMinn. R. 7080.1930, Table V1,000 gal
- North Carolina15A NCAC 18E .0801, Tables XIV and XV1,000 gal
- Pennsylvania25 Pa. Code § 73.31(a)900 gal
- Texas30 TAC §285.91(2) and Table III1,000 gal
- Virginia12VAC5-610-815, Table 5.2900 gal
- WashingtonWAC 246-272A-0232, Table VII1,000 gal
Every state we’ve read, for the same bedrooms, disposal and floor area. Other states: ask your county health department.
Georgia Rule 511-3-1-.05(3), as printed in DPH’s 2026 manual. Georgia: two compartments, the first at least 2/3 of the tank.
Both tables come from Karen Mancl’s 1984 estimate for year-round homes; Penn State assumes 50 gallons a person a day. A tank between rows reads on the smaller row, so the figure is on the sooner side. EPA: have it inspected at least every three years and pumped typically every three to five.
Fixr: “there are many older homes with smaller tanks of 750 or 1,000 gallons because the tank was never expanded with the addition of extra bathrooms or space in the home.” The pumping company can tell you your tank’s size; put it in above.
How we work it out
States set the minimum, by bedrooms. Each state’s onsite wastewater rule (or, in California, each county’s program) says the smallest tank a house may have, nearly always by the number of bedrooms. Florida and Texas also size by floor area, and use whichever gives the bigger tank. Minnesota and Georgia add half again for a garbage disposal; Pennsylvania’s flow already counts one. We read each rule on 2026-11-10 and quote it below. These are minimums: the county permit and a licensed designer set the tank actually installed, and it can be bigger.
| State | 2 bed | 3 bed | 4 bed | 5 bed | 6 bed | Rule |
|---|---|---|---|---|---|---|
| California (San Diego County) | 1,000 | 1,000 | 1,200 | 1,500 | 1,500 | San Diego County LAMP, Table 7.2-1, effective February 1, 2025 |
| Florida | 900 | 900 | 1,050 | 1,200 | 1,350 | Florida Rule 62-6.008, Tables I and II, effective July 16, 2013 |
| Georgia | 1,000 | 1,000 | 1,000 | 1,250 | 1,500 | Georgia Rule 511-3-1-.05(3), as printed in DPH’s 2026 manual |
| Minnesota | 1,000 | 1,000 | 1,500 | 1,500 | 2,000 | Minn. R. 7080.1930, Table V, published October 10, 2013 |
| North Carolina | 1,000 | 1,000 | 1,000 | 1,250 | 1,343 | 15A NCAC 18E .0801, Tables XIV and XV, amended June 1, 2026 |
| Pennsylvania | 900 | 900 | 1,250 | 1,400 | 1,550 | 25 Pa. Code § 73.31(a), as amended November 1997 |
| Texas | 750 | 1,000 | 1,250 | 1,250 | 1,313 | 30 TAC §285.91(2) and Table III, effective July 6, 2023 |
| Virginia | 750 | 900 | 1,200 | 1,500 | no row | 12VAC5-610-815, Table 5.2, effective July 1, 2000 |
| Washington | 1,000 | 1,000 | 1,000 | 1,250 | 1,500 | WAC 246-272A-0232, Table VII, effective April 1, 2025 |
Texas’s figures are without water saving devices; with them the rule’s lower flows give 750 gallons up to three bedrooms. North Carolina works six bedrooms and up from 120 gallons a day a bedroom. Virginia’s table stops at five bedrooms and San Diego County’s at six. Every other state: we haven’t read its rule yet, so the calculator says to check with your county health department rather than guess.
Two compartments. Most of these rules want the tank split by a wall or made of two tanks in series, with the bigger part first: Washington and Texas put half to two thirds of the volume in the first compartment, Georgia at least two thirds. Solids settle as sludge, grease floats as scum, and the clearer water in the middle flows on to the drainfield. The drawing uses Virginia’s typical tank shapes (12VAC5-610-815 Table 5.3).
How often to pump. EPA says a typical household tank is pumped every three to five years and inspected at least every three. Two published tables put a number on it for a tank size and household, both from Karen Mancl’s 1984 estimate for year-round homes: Penn State Extension’s (900 to 1,500 gallons) and Georgia DPH’s Table 15.L (1,000 to 2,500 gallons). A tank between rows reads on the smaller row.
| Tank | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|---|---|---|---|---|---|---|---|---|
| 900 gal (Penn State) | 11 | 5.2 | 3.3 | 2.3 | 1.7 | 1.3 | 1 | 0.8 |
| 1,000 gal (Penn State) | 12.4 | 5.9 | 3.7 | 2.6 | 2 | 1.5 | 1.2 | 1 |
| 1,250 gal (Penn State) | 15.6 | 7.5 | 4.8 | 3.4 | 2.6 | 2 | 1.7 | 1.4 |
| 1,500 gal (Penn State) | 18.9 | 9.1 | 5.9 | 4.2 | 3.3 | 2.6 | 2.1 | 1.8 |
| 1,750 gal (Georgia) | 22 | 11 | 6.9 | 5 | 3.9 | 3.1 | 2.6 | 2.2 |
| 2,000 gal (Georgia) | 25 | 12 | 8 | 5.9 | 4.5 | 3.7 | 3.1 | 2.6 |
| 2,250 gal (Georgia) | 29 | 14 | 9.1 | 6.7 | 5.2 | 4.2 | 3.5 | 3 |
| 2,500 gal (Georgia) | 32 | 16 | 10 | 7.5 | 5.9 | 4.8 | 4 | 4 |
What pumping costs. Fixr prices pumping by tank size, from $175 to $300 for 750 gallons up to $400 to $700 for 1,750. Thumbtack (Oct 2026), LawnStarter (Aug 2023) and Bob Vila (Jan 2023) each give one national range for any tank. We show them side by side and never average them. Fixr adds $100 to $200 for a riser when the lid is buried.
Older homes. Fixr notes that many older homes have 750 or 1,000 gallon tanks that were never enlarged when bathrooms or rooms were added. If you don’t know your tank’s size, the pumping company does; put it in to read the pumping table for it. To see roughly when your house went up, check when your house was built.
Keep water off the drainfield. EPA asks that roof drains and sump pumps be kept away from it. A dry well or a French drain can take that water somewhere else; site either well away from the tank and field. More water and drainage calculators are on the Spec My Yard home page.
Where the numbers come from
- San Diego County Local Agency Management Program for OWTS (effective February 1, 2025), section 7.2
- Florida Administrative Code 62-6.008, System Size Determinations (FL DEP)
- Georgia DPH, Manual for On-Site Sewage Management Systems (2026): Rule 511-3-1-.05 and Table 15.L
- Minnesota Rules 7080.1930, Septic Tank Capacity (Revisor of Statutes)
- 15A NCAC 18E .0801, Septic Tank Capacity Requirements (NC OAH)
- 15A NCAC 18E .0401, Design Daily Flow (NC OAH)
- 25 Pa. Code § 73.31, Standards for septic tanks
- TCEQ, 30 TAC Chapter 285 amendments, Rule Project 2021-030-285-CE (§285.32, §285.91)
- 12VAC5-610-815, Septic tank design (Virginia Administrative Code)
- WAC 246-272A-0232, Septic tank sizing (Washington Legislature)
- EPA SepticSmart: how to care for your septic system
- Penn State Extension: Septic tank pumping (updated November 3, 2026)
- Fixr: septic tank pumping cost (Jan 2025)
- Thumbtack: septic tank pumping cost (Oct 2026)
- LawnStarter: septic tank pumping cost (Aug 2023)
- Bob Vila: septic tank pumping cost (Jan 2023)
Water and drainage
The house
More calculators
- Pond volume and linerHow many gallons is my pond, and what liner and pump?
- Rainwater collectionHow many gallons will my roof collect?
- Rainfall totalsHow much rain did we get this week, month and year?
- Rain garden sizeHow big should my rain garden be?
- French drainHow much gravel and pipe for a French drain?
- French drain costWhat does a French drain cost per foot?
- Dry well sizeHow big a pit for my downspout?
- Mud kitchen plansHow do I build a mud kitchen sized for my kid?